Generator Panda 18 PVMV-N
General Technical Data
| Model.: | Panda 18 PVMV-N |
| Generator Type | Premium Line - Panda Standard Asynchronous (50 Hz)
|
| Generator Family | 18
|
| Generator Version.: | PVMV-N
|
| Additional Features |
|
| Area of Application.: | Vehicle Generator (V) |
| Frequency [Hz] | 50 |
| Generator manufacturer | Fischer Panda GmbH |
| Isolation class of windings | H |
| Nominal Speed [rpm] | 3000 |
| Voltage Regulation | VCS |
| Voltage Tolerance with VCS (up to 80% Performance) | ± 3V |
| Power rating factor Cos Pi | 0.85 |
| Excitation by | MKP Capacitors |
Single Phase Winding - Standard version
| Alternator Type | HP1 |
| Nominal Voltage in Volt | 230 |
| Nominal Performance in kW | 15.30 |
| Nominal Performance in kVA | 18.0 |
| Continuous Performance in kW | 13.7 |
| Continuous Performance in kVA | 16.2 |
| Number of Phases | 1 |
| Rated current each Phase in Ampere [A] | 66.5 |
| Continuous current each Phase in Ampere | 59.6 |
| Frequency [Hz] | 50 |
Three Phase Version (Optional)
| Alternator Type | HP3 |
| Nominal Voltage in Volt [V] | 400 |
| Nominal Performance in kW | 15.30 |
| Nominal Performance in kVA | 18.0 |
| Continuous Performance in kW | 13.8 |
| Continuous Performance in kVA | 16.2 |
| Number of Phases | 3 |
| Rated current each Phase in Ampere [A] | 22.1 |
| Continuous current each Phase in Ampere [A] | 19.9 |
| Frequency [Hz] | 50 |
3 Phase + 1 Phase (230V + 400V) (Optional)
The Alternator Type "DVS" (Dual Voltage System) comprises of two seperate windings (1-phase and 3-phase) within the stator. The windings are electrically isolated within same stator. This alternator type has a 12% reduction in performance, compared to the HP1 resp. HP3 winding type because the cross-section of the windings are reduced in order to fit both windings within the housing.
| DVS Winding - 1 phase | |
| Alternator Type | DVS |
| Nominal Voltage in in Volt [V] | 230 |
| Nominal Performance (P) in kW | 13.5 |
| Nominal Performance (S) in kVA | 15.9 |
| Continuous Performance in kW | 12.2 |
| Continuous Performance in kVA | 14.3 |
| Number of Phases | 1 |
| Rated current each Phase in Ampere [A] | 33.8 |
| Continuous current each Phase in Ampere [A] | 30.5 |
| Frequency [Hz] | 50 |
| DVS Winding - 3 phase | |
| Alternator Type | DVS |
| Nominal Voltage in Volt [V] | 3x400+N |
| Nominal Performance (P) in kW | 13.5 |
| Nominal Performance (S) in kVA | 15.9 |
| Continuous Performance in kW | 12.2 |
| Continuous Performance in kVA | 14.3 |
| Number of Phases | 3 |
| Rated current each Phase in Ampere [A] | 19.5 |
| Continuous current each Phase in Ampere [A] | 17.6 |
| Frequency in Hertz [Hz] | 50 |
All performance data applies to generator operation at 100m above sea level at 20°C. Performance reductions can occur when operating at greater heights.
Engine Data
| Engine Manufacturer | Kubota (KU) |
| Engine Type | D1105 |
| No. Cylinders | 3 |
| Displacement [cm3] | 1123 |
| Starter System | 12V (24V Optional) |
Sound Insulation Cover (Generator Housing / Sound Shield)
| Version | MPL 4DS |
| Sound Cover Type | MPL (Metal Professional Line) |
![]() | |
| Sound Insulation Material | 4DS |
| Dimensions Housing L x W x H *) *)) | Request - Please contact us |
| Total Weight of Generator with Capsule | Request - Please contact us |
| Sound Cover Upgrade Options (on request) | ->MPL 6DS |
Disclaimer
All technical data and specifications including dimensions, performance data, weight and material specifications are only valid when they are explicitly expressed in writing. All data should be considered only for approximation purposes because the data from these sources is gathered from current and previous models. As a result of continual product improvement and modification, the validity of technical data from these sources cannot be guaranteed. 3D-models are only provided on special request. It is the responsibility of the customer to ensure in all cases when ordering that technical data is valid and that the specifications meet his/her requirements.
*) The dimensions are for the sound insulation housing ONLY and do not include additional parts or fittings such as fasteners, closures or mounting brackets etc.
Therefore please note: You must consider the additional space will need to be calculated for the installation. This is of importance when planning the installation with respect of cables, hoses and mounting feet.
**) Generators with DVS windings are slightly longer than those with HP1 or HP3 windings. Specific dimensions are available on request.