Panda 15000 PVK-U

General Technical Data

Model.:Panda 15000 PVK-U
Generator TypeGenerators with regulated speed (3000 rpm 50 Hz)
  • Brushless
  • No signal noise
  • No rotating coils or diodes
  • Precise control
  • High protection rating
  • Perfect sine wave
  • Short-circuit stability
  • Water-cooled
  • Overload protection
Generator Family15000
  • external 12V fuel pump
Generator Version.:PVK-U
  • Assembly bolts pre-fitted to housing
  • Metal capsule with a heavy duty cover
  • Wide access hatch for easier access
  • No additional exhaust silencer required
  • Water-cooled exhaust silencer inside capsule
  • Requires external radiator
Article number.:0000375 ( <2017 : 04.01.03.027P)
Additional Features
  • Watercooling for Engine and Winding (Single-Circuit Cooling)
  • 12V/10A Alternator for charging the starter battery
Area of Application.:Vehicle Generator (V)
Frequency [Hz]50
Generator manufacturerFischer Panda GmbH
Isolation class of windingsH
Nominal Speed [rpm]3000
Voltage RegulationVCS
Voltage Tolerance with VCS (up to 80% Performance)± 3V
Power rating factor Cos Pi0.85
Excitation byMKP Capacitors

Electrical Alternator

Single Phase Winding - Standard version

Alternator TypeHP1
Nominal Voltage in Volt230
Power rating factor Cos Pi0.85
Nominal Performance in kW1)12.90
Nominal Performance in kVA1)15.2
Continuous Performance in kW1)11.6
Continuous Performance in kVA1)13.7
Number of Phases1
Frequency [Hz] 50

1) up to Panda 15000 / 12-4 cosPhi 0,85 for short take-off power to inductive loads, otherwise cosPhi1
1) from Panda 18 /17-4 on cosPhi 0,85 optional startup performance with compensation or starting current boost, otherwise cosPhi1

Three Phase Version (Optional)

Alternator TypeHP3
Nominal Voltage in Volt [V]400
Power rating factor Cos Pi0.85
Nominal Performance in kW1)12.90
Nominal Performance in kVA1)15.2
Continuous Performance in kW1)11.6
Continuous Performance in kVA1)13.7
Number of Phases3
Frequency [Hz]50

1) up to Panda 15000 / 12-4 cosPhi 0,85 for short take-off power to inductive loads, otherwise cosPhi1
1) from Panda 18 /17-4 on cosPhi 0,85 optional startup performance with compensation or starting current boost, otherwise cosPhi1

3 Phase + 1 Phase (230V + 400V) (Optional)

The Alternator Type "DVS" (Dual Voltage System) comprises of two seperate windings (1-phase and 3-phase) within the stator. The windings are electrically isolated within same stator. This alternator type has a 12% reduction in performance, compared to the HP1 resp. HP3 winding type because the cross-section of the windings are reduced in order to fit both windings within the housing.

 DVS Winding - 1 phaseDVS Winding - 3 phase
Alternator TypeDVS
Nominal Voltage in in Volt [V]2303x400+N
Power rating factor Cos Pi0.850.85
Number of Phases31
Nominal Performance (P) in kW1)11.411.4
Nominal Performance (S) in kVA1)13.413.4
Continuous Performance in kW1)10.310.3
Continuous Performance in kVA1)12.112.1
Rated current each Phase in Ampere [A]28.5 
Continuous current each Phase in Ampere [A]25.8 
Frequency [Hz]5050

1) up to Panda 15000 / 12-4 cosPhi 0,85 for short take-off power to inductive loads, otherwise cosPhi1
1) from Panda 18 /17-4 on cosPhi 0,85 optional startup performance with compensation or starting current boost, otherwise cosPhi1


All performance data applies to generator operation at 100m above sea level at 20°C. Performance reductions can occur when operating at greater heights.

Engine Data

Engine ManufacturerKubota (KU)
Engine TypeD902
No. Cylinders3
Displacement [cm3]898
Starter System12V (24V Optional)

Sound Insulation Cover (Generator Housing / Sound Shield)

 

VersionMPL 4DS
Article Number0000375
=< 2016 (04.01.03.027P)
CAD REF:0013463
Drawing Ref.FP1-039202
Sound Cover TypeMPL (Metal Professional Line)
Sound Insulation Material4DS
Dimensions Housing    L x W x H *) *)) Refer to Capsule Drawing of Sound Shield
Total Weight of Generator with Capsule Refer to Capsule Drawing of Sound Shield
Sound Cover Upgrade Options (on request)->MPL 6DS

Disclaimer

All technical data and specifications including dimensions, performance data, weight and material specifications are only valid when they are explicitly expressed in writing. All data should be considered only for approximation purposes because the data from these sources is gathered from current and previous models. As a result of continual product improvement and modification, the validity of technical data from these sources cannot be guaranteed. 3D-models are only provided on special request. It is the responsibility of the customer to ensure in all cases when ordering that technical data is valid and that the specifications meet his/her requirements.

*) The dimensions are for the sound insulation housing ONLY and do not include additional parts or fittings such as fasteners, closures or mounting brackets etc.

Therefore please note: You must consider the additional space will need to be calculated for the installation. This is of importance when planning the installation with respect of cables, hoses and mounting feet.

**) Generators with DVS windings are slightly longer than those with HP1 or HP3 windings. Specific dimensions are available on request.

Cooling: radiator / fans for vehicle generators

RD-D: DC Roof mounted radiators

Model - RD3.2 - 24V (Article number: 0000426)

(PDF)

Model - RD3.2 Trop - 24V (Article number: 0000425)

(PDF)

RD-A: AC Roof mounted radiators

Model - RD3.3 - 230V-50Hz (Article number: 0005837)

(PDF)

Model - RD3.3 Trop - 230V-50Hz (Article number: 0022812)

(PDF)

Model - RD4.2 - 230V-50Hz (Article number: 0005738)

(PDF)

RV-A: AC Side-/underneath (chassis mounted) radiators

Model - RV3.3 - 230V-50Hz (Article number: 0005839)

(PDF)

Model - RV3.3 Trop - 230V-50Hz (Article number: 0005817)

(PDF)

Model - RV5.2 - 230V-50Hz (Article number: 0005793)

(PDF)

Documentation

Control - P6+

Articlenumber : 0000139

      
 

Generator Handbook / Operators Manual

  

Capsule / Sound shield Drawing : FP1-039202

Articlenumber:0000375 ( < 2017 : 04.01.03.027P)
High Resolution Image: Panda 15000 PVK-U (2011 15000 pvk-u p1.JPG) 
High Resolution Image: Panda 15000 PVK-U (2011 15000 pvk-u p2.jpg) 
High Resolution Image: Panda 15000 PVK-U (2011 15000 pvk-u p3.jpg) 

Service- / installation kits and shock mountings

Note: Actual Service- / installation kits and shock mountings may differ from those displayed depending on Generator type.

Service kit

21.03.10.008


Service Kit "PLus"

21.03.10.068

Shock-mounting, captive

32.30.01.008