Panda 8000i PVK-U

General Technical Data

Model.:Panda 8000i PVK-U
Generator TypePanda i-Series (60 Hz)
    Generator Family8000i
      Generator Version.:PVK-U
      • Assembly bolts pre-fitted to housing
      • Metal capsule with a heavy duty cover
      • Wide access hatch for easier access
      • No additional exhaust silencer required
      • Water-cooled exhaust silencer inside capsule
      • Requires external radiator
      Article number.:
      Additional Features
      • Water-cooled Engine
      • 12V/10A Alternator for charging the starter battery
      Area of Application.:Vehicle Generator (V)
      Frequency [Hz]60
      Generator manufacturerFischer Panda GmbH
      Isolation class of windingsH
      Nominal Speed [rpm]2200-2800 rpm
      Voltage RegulationiControl2
      Power rating factor Cos Pi0.80

      Electrical Alternator

      Single Phase Version with Inverter Technology

      Engine Speed [rpm]2200 - 2800
      Nominal Voltage in Volt120
      Nominal Performance in kW)1)0-6.40
      Nominal Performance in kVA1)0-8.0
      Continuous Performance in kW1)0-5.7
      Continuous Performance in kVA1)0-7.2
      Number of Phases1
      Frequency [Hz]60

      1) cosPhi 0,8 up to 40°C ambient temperature, otherwise cosPhi 1 up to 50°C


      All performance data applies to generator operation at 100m above sea level at 20°C. Performance reductions can occur when operating at greater heights.

      Engine Data

      Engine ManufacturerKubota (KU)
      Engine TypeZ482
      No. Cylinders2
      Displacement [cm3]479
      Starter System12V (24V Optional)

      Sound Insulation Cover (Generator Housing / Sound Shield)

       

      VersionMPL 4DS
      Article Numberon request
      =< 2016 ()
      CAD REF:
      Drawing Ref.on request
      Sound Cover TypeMPL (Metal Professional Line)
      Sound Insulation Material4DS
      Dimensions Housing    L x W x H *) *)) Request - Please contact us
      Total Weight of Generator with Capsule Request - Please contact us
      Sound Cover Upgrade Options (on request)->MPL 6DS

      Disclaimer

      All technical data and specifications including dimensions, performance data, weight and material specifications are only valid when they are explicitly expressed in writing. All data should be considered only for approximation purposes because the data from these sources is gathered from current and previous models. As a result of continual product improvement and modification, the validity of technical data from these sources cannot be guaranteed. 3D-models are only provided on special request. It is the responsibility of the customer to ensure in all cases when ordering that technical data is valid and that the specifications meet his/her requirements.

      *) The dimensions are for the sound insulation housing ONLY and do not include additional parts or fittings such as fasteners, closures or mounting brackets etc.

      Therefore please note: You must consider the additional space will need to be calculated for the installation. This is of importance when planning the installation with respect of cables, hoses and mounting feet.

      **) Generators with DVS windings are slightly longer than those with HP1 or HP3 windings. Specific dimensions are available on request.

      Cooling: radiator / fans for vehicle generators

      Service- / installation kits and shock mountings

      Note: Actual Service- / installation kits and shock mountings may differ from those displayed depending on Generator type.

      Service kit

      21.03.10.008


      Service Kit "PLus"

      21.03.10.023

      Shock-mounting, captive

      32.30.01.005



      Share