Panda 4000s FC PMS

Print Preview as Datasheet

Fischer Panda Diesel Generator
Fischer Panda Diesel Generator
Fischer Panda Diesel Generator

General Technical Data

Model.:Panda 4000s FC PMS
Generator TypePanda s-Series Marine Synchronous Generators
    Generator Family4000s FC
    • Internal mechanical fuel pump
    Generator Version.:PMS
    • Easy to install
    • Suitable for internal installation
    • Low ambient temperatures
    • External control panel with cable
    • incl. Seawater impeller pump
    • incl. Freshwater (coolant) pump
    • Heat Exchanger for Engine and Winding (dual circuit cooling)
    Additional Features
      Area of Application.:Marine Generator (M)
      Frequency [Hz]50
      Generator manufacturerFischer Panda GmbH
      Isolation class of windingsH
      Frequency [Hz]50
      Nominal Speed [rpm]3000
      Nominal Performance [kW]3)3.80
      Nominal Performance [kVA] 3)4.5
      Voltage Regulationkeine
      Daten Winding (Single Phase Version) - Standard version
      Nominal Voltage in Volt230
      Nominal Performance in kW3.80
      Nominal Performance in kVA4.5
      Continuous Performance in kW3.4
      Continuous Performance in kVA4.0
      Number of Phases1
      Rated current each Phase in Ampere [A]16.5
      Continuous current each Phase in Ampere14.8
      Frequency [Hz] 50

      All performance data applies to generator operation at 100m above sea level at 20°C. Performance reductions can occur when operating at greater heights.

      Engine Data

      Engine ManufacturerFarymann (FA)
      Engine Type18W430
      No. Cylinders1
      Displacement [cm3]290
      Bore x Displacement82 x 55
      Starter System12V (24V Optional)

      Sound Insulation Cover (Generator Housing / Sound Shield)

      Fischer Panda Generator Capsule Drawing REF:FP1-012121.jpg

       

      VersionGFK 3D
      Sound Cover TypeGFK (Glass fibre reinforced polyester)
       
      Sound Insulation Material3D
      Dimensions Housing    L x W x H *) *)) Refer to Capsule Drawing of Sound Shield
      Total Weight of Generator with Capsule Refer to Capsule Drawing of Sound Shield
      Sound Cover Upgrade Options (on request)->MPL 4DS

      Disclaimer

      All technical data and specifications including dimensions, performance data, weight and material specifications are only valid when they are explicitly expressed in writing. All data should be considered only for approximation purposes because the data from these sources is gathered from current and previous models. As a result of continual product improvement and modification, the validity of technical data from these sources cannot be guaranteed. 3D-models are only provided on special request. It is the responsibility of the customer to ensure in all cases when ordering that technical data is valid and that the specifications meet his/her requirements.

      *) The dimensions are for the sound insulation housing ONLY and do not include additional parts or fittings such as fasteners, closures or mounting brackets etc.

      Therefore please note: You must consider the additional space will need to be calculated for the installation. This is of importance when planning the installation with respect of cables, hoses and mounting feet.

      **) Generators with DVS windings are slightly longer than those with HP1 or HP3 windings. Specific dimensions are available on request.