Panda 18 PSC

Print Preview as Datasheet

General Technical Data

Model.:Panda 18 PSC
Generator TypePremium Line - Panda Standard Asynchronous (50 Hz)
  • Brushless
  • No signal noise
  • No rotating coils or diodes
  • Precise control
  • High protection rating
  • Perfect sine wave
  • Short-circuit stability
  • Water-cooled
  • Overload protection
Generator Family18
  • external 12V fuel pump
Generator Version.:PSC
  • Electrical cabinet
  • Stainless steel sound cover
  • Voltage control system
  • Integrated radiator for temperatures from -20°C up to 35°C
  • Earthing point on frame
  • Fuel tank for 24 hours operation (with 50% load)
  • 12V starter battery
Additional Features
  • 12V/10A Alternator for charging the starter battery
Area of Application.:Vehicle Generator (V)
Frequency [Hz]50
Generator manufacturerFischer Panda GmbH
Isolation class of windingsH
Nominal Speed [rpm]3000
Voltage RegulationVCS
Voltage Tolerance with VCS (up to 80% Performance)± 3V
Power rating factor Cos Pi0.85
Excitation byMKP Capacitors

Single Phase Winding - Standard version

Alternator TypeHP1
Nominal Voltage in Volt230
Nominal Performance in kW15.30
Nominal Performance in kVA18.0
Continuous Performance in kW13.7
Continuous Performance in kVA16.2
Number of Phases1
Rated current each Phase in Ampere [A]66.5
Continuous current each Phase in Ampere59.6
Frequency [Hz] 50

Three Phase Version (Optional)

Alternator TypeHP3
Nominal Voltage in Volt [V]400
Nominal Performance in kW15.30
Nominal Performance in kVA18.0
Continuous Performance in kW13.8
Continuous Performance in kVA16.2
Number of Phases3
Rated current each Phase in Ampere [A]22.1
Continuous current each Phase in Ampere [A]19.9
Frequency [Hz]50

3 Phase + 1 Phase (230V + 400V) (Optional)

The Alternator Type "DVS" (Dual Voltage System) comprises of two seperate windings (1-phase and 3-phase) within the stator. The windings are electrically isolated within same stator. This alternator type has a 12% reduction in performance, compared to the HP1 resp. HP3 winding type because the cross-section of the windings are reduced in order to fit both windings within the housing.

DVS Winding - 1 phase
Alternator TypeDVS
Nominal Voltage in in Volt [V]230
Nominal Performance (P) in kW13.5
Nominal Performance (S) in kVA15.9
Continuous Performance in kW12.2
Continuous Performance in kVA14.3
Number of Phases1
Rated current each Phase in Ampere [A]33.8
Continuous current each Phase in Ampere [A]30.5
Frequency [Hz]50
DVS Winding - 3 phase
Alternator TypeDVS
Nominal Voltage in Volt [V]3x400+N
Nominal Performance (P) in kW13.5
Nominal Performance (S) in kVA15.9
Continuous Performance in kW12.2
Continuous Performance in kVA14.3
Number of Phases3
Rated current each Phase in Ampere [A]19.5
Continuous current each Phase in Ampere [A]17.6
Frequency in Hertz [Hz]50

All performance data applies to generator operation at 100m above sea level at 20°C. Performance reductions can occur when operating at greater heights.

Engine Data

Engine ManufacturerKubota (KU)
Engine TypeD1105
No. Cylinders3
Displacement [cm3]1123
Starter System12V (24V Optional)

Sound Insulation Cover (Generator Housing / Sound Shield)

 

VersionMPL 4DS
Sound Cover TypeMPL (Metal Professional Line)
 
Sound Insulation Material4DS
Dimensions Housing    L x W x H *) *)) Request - Please contact us
Total Weight of Generator with Capsule Request - Please contact us
Sound Cover Upgrade Options (on request)->MPL 6DS

Disclaimer

All technical data and specifications including dimensions, performance data, weight and material specifications are only valid when they are explicitly expressed in writing. All data should be considered only for approximation purposes because the data from these sources is gathered from current and previous models. As a result of continual product improvement and modification, the validity of technical data from these sources cannot be guaranteed. 3D-models are only provided on special request. It is the responsibility of the customer to ensure in all cases when ordering that technical data is valid and that the specifications meet his/her requirements.

*) The dimensions are for the sound insulation housing ONLY and do not include additional parts or fittings such as fasteners, closures or mounting brackets etc.

Therefore please note: You must consider the additional space will need to be calculated for the installation. This is of importance when planning the installation with respect of cables, hoses and mounting feet.

**) Generators with DVS windings are slightly longer than those with HP1 or HP3 windings. Specific dimensions are available on request.