Panda 45 PMS

Print Preview as Datasheet

Fischer Panda Diesel Generator
Fischer Panda Diesel Generator
Fischer Panda Diesel Generator

General Technical Data

Model.:Panda 45 PMS
Generator TypePremium Line - Panda Standard Asynchronous (50 Hz)
  • Brushless
  • No signal noise
  • No rotating coils or diodes
  • Precise control
  • High protection rating
  • Perfect sine wave
  • Short-circuit stability
  • Water-cooled
  • Overload protection
Generator Family45
  • external 12V fuel pump
Generator Version.:PMS
  • Easy to install
  • Suitable for internal installation
  • Low ambient temperatures
  • External control panel with cable
  • incl. Seawater impeller pump
  • incl. Freshwater (coolant) pump
  • Heat Exchanger for Engine and Winding (dual circuit cooling)
Additional Features
  • Alternator for charging the starter battery
Area of Application.:Marine Generator (M)
Frequency [Hz]50
Generator manufacturerFischer Panda GmbH
Isolation class of windingsH
Nominal Speed [rpm]3000
Voltage RegulationVCS
Voltage Tolerance with VCS (up to 80% Performance)± 3V
Power rating factor Cos Pi1.00
Excitation byMKP Capacitors

Single Phase Winding - Optional

Alternator TypeHP1
Nominal Voltage in Volt230
Nominal Performance in kW39.00
Nominal Performance in kVA39.0
Continuous Performance in kW35.1
Continuous Performance in kVA35.1
Number of Phases1
Rated current each Phase in Ampere [A]169.6
Continuous current each Phase in Ampere152.6
Frequency [Hz] 50

Three Phase Version (Standard version)

Alternator TypeHP3
Nominal Voltage in Volt [V]400
Nominal Performance in kW39.00
Nominal Performance in kVA39.0
Continuous Performance in kW35.1
Continuous Performance in kVA35.1
Number of Phases3
Rated current each Phase in Ampere [A]56.4
Continuous current each Phase in Ampere [A]50.7
Frequency [Hz]50

All performance data applies to generator operation at 100m above sea level at 20°C. Performance reductions can occur when operating at greater heights.

Engine Data

Engine ManufacturerLombardini (LO)
Engine TypeLDW 2204MT
No. Cylinders4
Displacement [cm3]2199
Starter System12V (24V Optional)

Sound Insulation Cover (Generator Housing / Sound Shield)

Fischer Panda Generator Capsule Drawing REF:FP1-021033.jpg

 

VersionMPL 4DS
Sound Cover TypeMPL (Metal Professional Line)
 
Sound Insulation Material4DS
Dimensions Housing    L x W x H *) *)) Refer to Capsule Drawing of Sound Shield
Total Weight of Generator with Capsule Refer to Capsule Drawing of Sound Shield
Sound Cover Upgrade Options (on request)->MPL 6DS

Disclaimer

All technical data and specifications including dimensions, performance data, weight and material specifications are only valid when they are explicitly expressed in writing. All data should be considered only for approximation purposes because the data from these sources is gathered from current and previous models. As a result of continual product improvement and modification, the validity of technical data from these sources cannot be guaranteed. 3D-models are only provided on special request. It is the responsibility of the customer to ensure in all cases when ordering that technical data is valid and that the specifications meet his/her requirements.

*) The dimensions are for the sound insulation housing ONLY and do not include additional parts or fittings such as fasteners, closures or mounting brackets etc.

Therefore please note: You must consider the additional space will need to be calculated for the installation. This is of importance when planning the installation with respect of cables, hoses and mounting feet.

**) Generators with DVS windings are slightly longer than those with HP1 or HP3 windings. Specific dimensions are available on request.