Panda 8000i PVK-U

Print Preview as Datasheet

General Technical Data

Model.:Panda 8000i PVK-U
Generator TypePanda i-Series (50 Hz)
  • Digital display
  • Environmentally friendly - low fuel consumption
  • Variable speed - load-dependent
  • Easy to install - reduces costs
  • Small size and low weight - compact installation
  • High starting capacity for air conditioners / diving compressors
  • Highly efficient - maximum energy
  • Pure sinus wave is ideal for sensitive electronics
  • 230V AC output - reliable power supply
Generator Family8000i
  • external 12V fuel pump
Generator Version.:PVK-U
  • Assembly bolts pre-fitted to housing
  • Metal capsule with a heavy duty cover
  • Wide access hatch for easier access
  • No additional exhaust silencer required
  • Water-cooled exhaust silencer inside capsule
  • Requires external radiator
  • incl. Freshwater (coolant) pump
Additional Features
  • Water-cooled Engine
  • 12V/10A Alternator for charging the starter battery
Area of Application.:Vehicle Generator (V)
Frequency [Hz]50
Generator manufacturerFischer Panda GmbH
Isolation class of windingsH
Nominal Speed [rpm]2200-2800
Voltage RegulationiControl
Power rating factor Cos Pi0.80

Single Phase Version with Inverter Technology

Engine Speed [rpm]2200 - 2800
Nominal Voltage in Volt230
Nominal Performance in kW)1)0-6.40
Nominal Performance in kVA1)0-8.0
Continuous Performance in kW1)0-5.7
Continuous Performance in kVA1)0-7.2
Number of Phases1
Max. Rated Inrush Current in Ampere75A
Frequency [Hz]50

1) cosPhi 0,8 up to 40°C ambient temperature, otherwise cosPhi 1 up to 50°C


All performance data applies to generator operation at 100m above sea level at 20°C. Performance reductions can occur when operating at greater heights.

Engine Data

Engine ManufacturerKubota (KU)
Engine TypeZ482
No. Cylinders2
Displacement [cm3]479
Starter System12V (24V Optional)

Sound Insulation Cover (Generator Housing / Sound Shield)

 

VersionMPL 4DS
Sound Cover TypeMPL (Metal Professional Line)
 
Sound Insulation Material4DS
Dimensions Housing    L x W x H *) *)) Request - Please contact us
Total Weight of Generator with Capsule Request - Please contact us
Sound Cover Upgrade Options (on request)->MPL 6DS

Disclaimer

All technical data and specifications including dimensions, performance data, weight and material specifications are only valid when they are explicitly expressed in writing. All data should be considered only for approximation purposes because the data from these sources is gathered from current and previous models. As a result of continual product improvement and modification, the validity of technical data from these sources cannot be guaranteed. 3D-models are only provided on special request. It is the responsibility of the customer to ensure in all cases when ordering that technical data is valid and that the specifications meet his/her requirements.

*) The dimensions are for the sound insulation housing ONLY and do not include additional parts or fittings such as fasteners, closures or mounting brackets etc.

Therefore please note: You must consider the additional space will need to be calculated for the installation. This is of importance when planning the installation with respect of cables, hoses and mounting feet.

**) Generators with DVS windings are slightly longer than those with HP1 or HP3 windings. Specific dimensions are available on request.

RD-A: AC Roof mounted radiators

ModelRD3.3 - S350
Weight (dry)36 kg
ModelRD3.3 Trop - S350
Weight (dry)42 kg
ModelRD4.2 - FE040
Weight (dry)32 kg
Fan TypeFE040

RD-D: DC Roof mounted radiators

ModelRD 1.2
Weight (dry)18 kg
Number of fans1
VoltageDC (Gleichspannung)
ModelRD 2.2
Weight (dry)29 kg

RV-D: Side-/underneath (chassis mounted) radiators DC

ModelRV2.2
Weight (dry)21 kg

Service-/installation kits and shock mountings

Service kit21.03.10.008P
Service Kit "PLus"21.03.10.023P
Shock-mounting, captive32.30.01.005
Deutsch Language VersionEnglish Language Version