Datasheet: Marine Generator - Panda 6000 ND PMS

Fischer Panda Diesel Generator Marine Generator - Panda 6000 ND PMS target=_new
Fischer Panda Diesel Generator Marine Generator - Panda 6000 ND PMSFischer Panda Diesel Generator Marine Generator - Panda 6000 ND PMSFischer Panda Diesel Generator Marine Generator - Panda 6000 ND PMS
Fischer Panda Diesel Generator Marine Generator - Panda 6000 ND PMSFischer Panda Diesel Generator Marine Generator - Panda 6000 ND PMSFischer Panda Diesel Generator Marine Generator - Panda 6000 ND PMS
Fischer Panda Diesel Generator Marine Generator - Panda 6000 ND PMSFischer Panda Diesel Generator Marine Generator - Panda 6000 ND PMS 
Acutal generator may differ slightly to that in picture

 


 

A - General technical data Marine Generator - Panda 6000 ND PMS
Model.:Panda 6000 ND PMS
 
Area of Application.:M (Marine Generator) 
Generator Version.:PMS 
Generator TypePSA - Basic Line - Panda Standard Asynchronous 
Frequency50[Hz]
Nominal Speed3000[rpm]
Alternator Standard Version.:HP1 
Nominal Performance5.10[kW]
Nominal Performance6.0[kVA]
Continuous Performance4.6[kW]
Continuous Performance5.4[kVA]
B - Alternator General Data
Power rating factor Cos Pi0.85 
Voltage Regulationkeine 
Generator manufacturerFISCHER PANDA 
Shielded to prevent radio interferenceaccordance with VDE 0875 
Isolation class of windingsF 
Excitation byMKP Capacitors 
 
C - Performance Data for electrical Generator (Alternator)
Daten HP1 Coil (Single Phase Version) - Standard version
Alternator Type "HP1" (High Performance 1 phase Winding), 230 V only.
Alternator TypeHP1 
Nominal Voltage in Volt230[Volt]
Nominal Performance in kW5.10[kW]
Nominal Performance in kVA6.0[kVA]
Continuous Performance in kW4.6[kW]
Continuous Performance in kVA5.4[kVA]
Number of Phases1 
Rated current each Phase in Ampere26.1[A]
Continuous current each Phase in Ampere23.5[A]
Frequency in Hertz50[Hz]
 
Daten HP3 Coil (Three Phase Version) - Optional - This version available on request
Alternator Type "HP3" (High Performance 3 phase winding). Produces 3-phase current (400 V), but 230 V single phase is included, but must be distributed to 3 phases.
Alternator TypeHP3 
Nominal Voltage in Volt3x400+N[Volt]
Nominal Performance in kW5.10[kW]
Nominal Performance in kVA6.0[kVA]
Continuous Performance in kW4.6[kW]
Continuous Performance in kVA5.4[kVA]
Number of Phases3 
Rated current each Phase in Ampere8.7[A]
Continuous current each Phase in Ampere7.8[A]
Frequency in Hertz50[Hz]
 
Daten DVS Coil (3 phase + 1 phase Version) - Optional - This version available on request
The Alternator Type "DVS" (Dual Voltage System) comprises of two seperate windings (1-phase and 3-phase) within the stator. The alternator comprises a 3-phase (400V) winding and a 1-phase (230V) winding. The windings are electrically isolated within same stator. This alternator type has a 12% reduction in performance, compared to the HP1 resp. HP3 winding type because the cross-section of the windings are reduced in order to fit both windings within the housing.
DVS Winding - 1 phase
Alternator TypeDVS 
Nominal Voltage in in Volt230[Volt]
Nominal Performance (P) in kW4.5[kW]
Nominal Performance (S) in kVA5.3[kVA]
Continuous Performance in kW4.0[kW]
Continuous Performance in kVA4.8[kVA]
Number of Phases1 
Rated current each Phase in Ampere23.0[A]
Continuous current each Phase in Ampere20.9[A]
Frequency50[Hz]
DVS Winding - 3 phase
Alternator TypeDVS 
Nominal Voltage in Volt3x400+N[Volt]
Nominal Performance (P) in kW4.5[kW]
Nominal Performance (S) in kVA5.3[kVA]
Continuous Performance in kW4.0[kW]
Continuous Performance in kVA4.8[kVA]
Number of Phases3 
Rated current each Phase in Ampere7.7[A]
Continuous current each Phase in Ampere6.9[A]
Frequency in Hertz50[Hz]
 
 
D - Sound Insulation Cover (generator housing)
 
P6000_ND_PMS_1A-FP1-002712_preview.jpg
Capsule GFK 3D - Standard Sound Insulation Capsule
DescriptionGFK 3D
MaterialGFK (Glass fibre reinforced polyester)
Sound Insulation Material3 layers with a total thickness of 30 mm
Dimensions Housing    L x W x H *) Refer to Capsule Drawing of Sound Shield
Total Weight of Generator with Capsule Refer to Capsule Drawing of Sound Shield

*) The dimensions are for the sound insulation housing ONLY and do not include additional parts or fittings such as fasteners, closures or mounting brackets etc.
Therefore please Note You must consider the additional space will need to be calculated for the installation. This is of importance when planning the installation with respect of cables, hoses and mounting feet.

 
E - Engine Data
Engine ManufacturerKubota (KU) 
Engine TypeZ482 
No. Cylinders2 
Bore and Displacment479[ccm]
 
F - Downloads
Capsule Drawings
P6000_ND_PMS_1A-FP1-002712.jpgP6000 ND PMS 1A-FP1-002712.pdf
Installation and Service Kits
Installation_Service_Guide_2009_Buch_R0101.jpgInstallation Service Guide 2009 Buch R01.pdf
 

Disclaimer

All technical data and specifications including dimensions, performance data, weight and material specifications are only valid when they are explicitly expressed in writing. All data should be considered only for approximation purposes because the data from these sources is gathered from current and previous models. As a result of continual product improvement and modification, the validity of technical data from these sources cannot be guaranteed. 3D-models are only provided on special request. It is the responsibility of the customer to ensure in all cases when ordering that technical data is valid and that the specifications meet his/her requirements.

Primary Power:
Fischer Panda Marine 6.0 kW Generator
Fischer Panda Marine 6.0 kW Genset
Fischer Panda Marine 6.0 kW Power Generator
Fischer Panda Marine 6.0 kW Diesel Generator
Fischer Panda Marine 6.0 kW Electric Generator

Keywords: