| A - General technical data Marine Generator - Panda 4,5 ND PMS | ||
| Model.: | Panda 4,5 ND PMS | |
| Area of Application.: | M (Marine Generator) | |
| Generator Version.: | PMS | |
| Generator Type | PSA - Basic Line - Panda Standard Asynchronous | |
| Frequency | 50 | [Hz] |
| Nominal Speed | 3000 | [rpm] |
| Alternator Standard Version.: | HP1 | |
| Nominal Performance | 3.80 | [kW] |
| Nominal Performance | 4.5 | [kVA] |
| Continuous Performance | 3.4 | [kW] |
| Continuous Performance | 4.0 | [kVA] |
| B - Alternator General Data | ||
| Power rating factor Cos Pi | 0.85 | |
| Voltage Regulation | keine | |
| Generator manufacturer | FISCHER PANDA | |
| Shielded to prevent radio interference | accordance with VDE 0875 | |
| Isolation class of windings | F | |
| Excitation by | MKP Capacitors | |
| C - Performance Data for electrical Generator (Alternator) | ||
| Daten HP1 Coil (Single Phase Version) - Standard version | ||
| Alternator Type "HP1" (High Performance 1 phase Winding), 230 V only. | ||
| Alternator Type | HP1 | |
| Nominal Voltage in Volt | 230 | [Volt] |
| Nominal Performance in kW | 3.80 | [kW] |
| Nominal Performance in kVA | 4.5 | [kVA] |
| Continuous Performance in kW | 3.4 | [kW] |
| Continuous Performance in kVA | 4.0 | [kVA] |
| Number of Phases | 1 | |
| Rated current each Phase in Ampere | 19.6 | [A] |
| Continuous current each Phase in Ampere | 17.4 | [A] |
| Frequency in Hertz | 50 | [Hz] |
| Daten HP3 Coil (Three Phase Version) - Optional - This version available on request | ||
| Alternator Type "HP3" (High Performance 3 phase winding). Produces 3-phase current (400 V), but 230 V single phase is included, but must be distributed to 3 phases. | ||
| Alternator Type | HP3 | |
| Nominal Voltage in Volt | 3x400+N | [Volt] |
| Nominal Performance in kW | 3.80 | [kW] |
| Nominal Performance in kVA | 4.5 | [kVA] |
| Continuous Performance in kW | 3.4 | [kW] |
| Continuous Performance in kVA | 4.0 | [kVA] |
| Number of Phases | 3 | |
| Rated current each Phase in Ampere | 6.5 | [A] |
| Continuous current each Phase in Ampere | 5.8 | [A] |
| Frequency in Hertz | 50 | [Hz] |
| Daten DVS Coil (3 phase + 1 phase Version) - Optional - This version available on request | ||
| The Alternator Type "DVS" (Dual Voltage System) comprises of two seperate windings (1-phase and 3-phase) within the stator. The alternator comprises a 3-phase (400V) winding and a 1-phase (230V) winding. The windings are electrically isolated within same stator. This alternator type has a 12% reduction in performance, compared to the HP1 resp. HP3 winding type because the cross-section of the windings are reduced in order to fit both windings within the housing. | ||
| DVS Winding - 1 phase | ||
| Alternator Type | DVS | |
| Nominal Voltage in in Volt | 230 | [Volt] |
| Nominal Performance (P) in kW | 3.3 | [kW] |
| Nominal Performance (S) in kVA | 3.9 | [kVA] |
| Continuous Performance in kW | 3.0 | [kW] |
| Continuous Performance in kVA | 3.5 | [kVA] |
| Number of Phases | 1 | |
| Rated current each Phase in Ampere | 17.0 | [A] |
| Continuous current each Phase in Ampere | 15.2 | [A] |
| Frequency | 50 | [Hz] |
| DVS Winding - 3 phase | ||
| Alternator Type | DVS | |
| Nominal Voltage in Volt | 3x400+N | [Volt] |
| Nominal Performance (P) in kW | 3.3 | [kW] |
| Nominal Performance (S) in kVA | 3.9 | [kVA] |
| Continuous Performance in kW | 3.0 | [kW] |
| Continuous Performance in kVA | 3.5 | [kVA] |
| Number of Phases | 3 | |
| Rated current each Phase in Ampere | 5.6 | [A] |
| Continuous current each Phase in Ampere | 5.1 | [A] |
| Frequency in Hertz | 50 | [Hz] |
| D - Sound Insulation Cover (generator housing) | ||
| Capsule MPL 4DS - Standard Sound Insulation Capsule | ||
| Description | MPL 4DS | |
| Material | MPL | |
| Sound Insulation Material | 4DS - 4 to 5 layers, thickness approx. 40 mm | |
| Dimensions Housing L x W x H *) | Request - Please contact us | |
| Total Weight of Generator with Capsule | Request - Please contact us | |
*) The dimensions are for the sound insulation housing ONLY and do not include additional parts or fittings such as fasteners, closures or mounting brackets etc. | ||
| E - Engine Data | ||
| Engine Manufacturer | Farymann (FA) | |
| Engine Type | 18W430M5 | |
| No. Cylinders | 1 | |
| Bore and Displacment | 290 | [ccm] |
| Bore x Displacment | 82 x 55 | |
| F - Downloads | ||
| Generator Partslist | |
![]() | Partlist P4,5ND PMS.V02.pdf |
| Installation and Service Kits | |
![]() | Installation Service Guide 2009 Buch R01.pdf |
Disclaimer
All technical data and specifications including dimensions, performance data, weight and material specifications are only valid when they are explicitly expressed in writing. All data should be considered only for approximation purposes because the data from these sources is gathered from current and previous models. As a result of continual product improvement and modification, the validity of technical data from these sources cannot be guaranteed. 3D-models are only provided on special request. It is the responsibility of the customer to ensure in all cases when ordering that technical data is valid and that the specifications meet his/her requirements.
Primary Power:
Fischer Panda Marine 4.5 kW Generator
Fischer Panda Marine 4.5 kW Genset
Fischer Panda Marine 4.5 kW Power Generator
Fischer Panda Marine 4.5 kW Diesel Generator
Fischer Panda Marine 4.5 kW Electric Generator
Keywords: