Datasheet: Marine Generator - Panda 40 YA PMS

 


 

A - General technical data Marine Generator - Panda 40 YA PMS
Model.:Panda 40 YA PMS
 
Area of Application.:M (Marine Generator) 
Generator Version.:PMS 
Generator TypePSA - Premium Line - Panda Standard Asynchronous 
Frequency50[Hz]
Nominal Speed3000[rpm]
Alternator Standard Version.:HP3 
Nominal Performance35.00[kW]
Nominal Performance41.2[kVA]
Continuous Performance31.5[kW]
Continuous Performance37.1[kVA]
B - Alternator General Data
Power rating factor Cos Pi0.85 
Voltage RegulationVCS 
Voltage Tolerance with VCS (up to 80% Performance± 3[Volt]
Generator manufacturerFISCHER PANDA 
Shielded to prevent radio interferenceaccordance with VDE 0875 
Isolation class of windingsF 
Excitation byMKP Capacitors 
 
C - Performance Data for electrical Generator (Alternator)
Daten HP3 Coil (Three Phase Version) - Standard version
Alternator Type "HP3" (High Performance 3 phase winding). Produces 3-phase current (400 V), but 230 V single phase is included, but must be distributed to 3 phases.
Alternator TypeHP3 
Nominal Voltage in Volt3x400+N[Volt]
Nominal Performance in kW35.00[kW]
Nominal Performance in kVA41.2[kVA]
Continuous Performance in kW31.5[kW]
Continuous Performance in kVA37.1[kVA]
Number of Phases3 
Rated current each Phase in Ampere59.5[A]
Continuous current each Phase in Ampere53.6[A]
Frequency in Hertz50[Hz]
 
 
D - Sound Insulation Cover (generator housing)
 
P40_YA_PMS_preview.jpg
Capsule MPL 4DS - Standard Sound Insulation Capsule
DescriptionMPL 4DS
MaterialMPL
Sound Insulation Material4DS - 4 to 5 layers, thickness approx. 40 mm
Dimensions Housing    L x W x H *) Refer to Capsule Drawing of Sound Shield
Total Weight of Generator with Capsule Refer to Capsule Drawing of Sound Shield

*) The dimensions are for the sound insulation housing ONLY and do not include additional parts or fittings such as fasteners, closures or mounting brackets etc.
Therefore please Note You must consider the additional space will need to be calculated for the installation. This is of importance when planning the installation with respect of cables, hoses and mounting feet.

 
E - Engine Data
Engine ManufacturerYanmar (YA) 
Engine Type4TNV84T 
No. Cylinders4 
Bore and Displacment1995[ccm]
Bore x Displacment84 x 90 
 
F - Downloads
Capsule Drawings
P40_YA_PMS.jpgP40 YA PMS.pdf
 

Disclaimer

All technical data and specifications including dimensions, performance data, weight and material specifications are only valid when they are explicitly expressed in writing. All data should be considered only for approximation purposes because the data from these sources is gathered from current and previous models. As a result of continual product improvement and modification, the validity of technical data from these sources cannot be guaranteed. 3D-models are only provided on special request. It is the responsibility of the customer to ensure in all cases when ordering that technical data is valid and that the specifications meet his/her requirements.

Primary Power:
Fischer Panda Marine 41.2 kW Generator
Fischer Panda Marine 41.2 kW Genset
Fischer Panda Marine 41.2 kW Power Generator
Fischer Panda Marine 41.2 kW Diesel Generator
Fischer Panda Marine 41.2 kW Electric Generator

Keywords: