Datasheet: Marine Generator - Panda 14.000 NE PMS

 


 

C - Performance Data for electrical Generator (Alternator)
Daten HP1 Coil (Single Phase Version) - Standard version
Alternator Type "HP1" (High Performance 1 phase Winding), 230 V only.
Alternator TypeHP1 
Nominal Voltage in Volt230[Volt]
Nominal Performance in kW11.90[kW]
Nominal Performance in kVA14.0[kVA]
Continuous Performance in kW10.7[kW]
Continuous Performance in kVA12.6[kVA]
Number of Phases1 
Rated current each Phase in Ampere60.9[A]
Continuous current each Phase in Ampere54.8[A]
Frequency in Hertz50[Hz]
 
Daten HP3 Coil (Three Phase Version) - Optional - This version available on request
Alternator Type "HP3" (High Performance 3 phase winding). Produces 3-phase current (400 V), but 230 V single phase is included, but must be distributed to 3 phases.
Alternator TypeHP3 
Nominal Voltage in Volt3x400+N[Volt]
Nominal Performance in kW11.90[kW]
Nominal Performance in kVA14.0[kVA]
Continuous Performance in kW10.7[kW]
Continuous Performance in kVA12.6[kVA]
Number of Phases3 
Rated current each Phase in Ampere20.2[A]
Continuous current each Phase in Ampere18.2[A]
Frequency in Hertz50[Hz]
 
Daten DVS Coil (3 phase + 1 phase Version) - Optional - This version available on request
The Alternator Type "DVS" (Dual Voltage System) comprises of two seperate windings (1-phase and 3-phase) within the stator. The alternator comprises a 3-phase (400V) winding and a 1-phase (230V) winding. The windings are electrically isolated within same stator. This alternator type has a 12% reduction in performance, compared to the HP1 resp. HP3 winding type because the cross-section of the windings are reduced in order to fit both windings within the housing.
DVS Winding - 1 phase
Alternator TypeDVS 
Nominal Voltage in in Volt230[Volt]
Nominal Performance (P) in kW10.5[kW]
Nominal Performance (S) in kVA12.4[kVA]
Continuous Performance in kW9.5[kW]
Continuous Performance in kVA11.2[kVA]
Number of Phases1 
Rated current each Phase in Ampere53.9[A]
Continuous current each Phase in Ampere48.7[A]
Frequency50[Hz]
DVS Winding - 3 phase
Alternator TypeDVS 
Nominal Voltage in Volt3x400+N[Volt]
Nominal Performance (P) in kW10.5[kW]
Nominal Performance (S) in kVA12.4[kVA]
Continuous Performance in kW9.5[kW]
Continuous Performance in kVA11.2[kVA]
Number of Phases3 
Rated current each Phase in Ampere17.9[A]
Continuous current each Phase in Ampere16.2[A]
Frequency in Hertz50[Hz]
 
 

Disclaimer

All technical data and specifications including dimensions, performance data, weight and material specifications are only valid when they are explicitly expressed in writing. All data should be considered only for approximation purposes because the data from these sources is gathered from current and previous models. As a result of continual product improvement and modification, the validity of technical data from these sources cannot be guaranteed. 3D-models are only provided on special request. It is the responsibility of the customer to ensure in all cases when ordering that technical data is valid and that the specifications meet his/her requirements.

Primary Power:
Fischer Panda Marine 14.0 kW Generator
Fischer Panda Marine 14.0 kW Genset
Fischer Panda Marine 14.0 kW Power Generator
Fischer Panda Marine 14.0 kW Diesel Generator
Fischer Panda Marine 14.0 kW Electric Generator

Keywords: