Model.: | AGT-DC 6000-24V PVMV-N |
Generator Type | Direct Current (DC) Line
|
Generator Family | 6000-24V
|
Generator Version.: | PVMV-N
|
Article number.: | 0015433 |
Additional Features |
|
Area of Application.: | Vehicle Generator (V) |
Frequency [Hz] | 400 |
Generator manufacturer | Fischer Panda GmbH |
Isolation class of windings | H |
Winding Type | Permanent Magnet |
Charging Voltage | Direct |
Engine Speed [rpm] | 2400 - 3200 |
Nominal Performance 1) | 4.80 |
Continuous Performance [kW] 1) | 04.80 |
Nominal Voltage [V] 1) | 12V - 400V versions available. |
Constant current rate [A] | Current dependent upon voltage |
Peak current rate [A] | Current dependent upon voltage |
All performance data applies to generator operation at 100m above sea level at 20°C. Performance reductions can occur when operating at greater heights.
Engine Manufacturer | Kubota (KU) |
Engine Type | Z482 |
No. Cylinders | 2 |
Displacement [cm3] | 479 |
Starter System | 12V (24V Optional) |
Version | GFK 4DS |
Article Number | 0015433 CAD REF:0005437 |
Drawing Ref. | FP1-024944 |
Sound Cover Type | GFK (Glass fibre reinforced polyester) |
Sound Insulation Material | 4DS |
Dimensions Housing L x W x H *) *)) | Refer to Capsule Drawing of Sound Shield |
Total Weight of Generator with Capsule | Refer to Capsule Drawing of Sound Shield |
Sound Cover Upgrade Options (on request) | ->MPL 4DS |
Disclaimer
All technical data and specifications including dimensions, performance data, weight and material specifications are only valid when they are explicitly expressed in writing. All data should be considered only for approximation purposes because the data from these sources is gathered from current and previous models. As a result of continual product improvement and modification, the validity of technical data from these sources cannot be guaranteed. 3D-models are only provided on special request. It is the responsibility of the customer to ensure in all cases when ordering that technical data is valid and that the specifications meet his/her requirements.
*) The dimensions are for the sound insulation housing ONLY and do not include additional parts or fittings such as fasteners, closures or mounting brackets etc.
Therefore please note: You must consider the additional space will need to be calculated for the installation. This is of importance when planning the installation with respect of cables, hoses and mounting feet.
**) Generators with DVS windings are slightly longer than those with HP1 or HP3 windings. Specific dimensions are available on request.
Note: Actual Service- / installation kits and shock mountings may differ from those displayed depending on Generator type.
Service kit
0000693 for Serial Numbers : SNo <= C02-034-061
0000693 for Serial Numbers : SNo >= C02-034-062
Service Kit "PLus"
0006364 for Serial Numbers : SNo <= C02-034-061
0006365 for Serial Numbers : SNo >= C02-034-062
Shock-mounting, captive
0002753 for Serial Numbers : SNo <= C02-034-061
0002753 for Serial Numbers : SNo >= C02-034-062