Panda 24 PVK-UK

General Technical Data

Model.:Panda 24 PVK-UK
Generator TypeGenerators with regulated speed (3000 rpm 50 Hz)
  • Brushless
  • No signal noise
  • No rotating coils or diodes
  • Precise control
  • High protection rating
  • Perfect sine wave
  • Short-circuit stability
  • Water-cooled
  • Overload protection
Generator Family24
    Generator Version.:PVK-UK
    • Metal capsule with a heavy duty cover
    • Wide access hatch for easier access
    • Sound insulation capsule
    • No additional exhaust silencer required
    • Integrated radiator and cooling system
    • Designed for mounting externally on the vehicle chassis
    Article number.:0015348
    Additional Features
    • Watercooling for Engine and Winding (Single-Circuit Cooling)
    Area of Application.:Vehicle Generator (V)
    Frequency [Hz]50
    Generator manufacturerFischer Panda GmbH
    Isolation class of windingsH
    Nominal Speed [rpm]3000
    Voltage RegulationVCS
    Voltage Tolerance with VCS (up to 80% Performance)± 3V
    Power rating factor Cos Pi0.85
    Excitation byMKP Capacitors

    Electrical Alternator

    Windings available:

    Single Phase Winding - Standard version

    Alternator TypeHP1
    Nominal Voltage in Volt230
    Power rating factor Cos Pi0.85
    Nominal Performance in kW1)20.4
    Nominal Performance in kVA1)24.0
    Continuous Performance in kW1)18.3
    Continuous Performance in kVA1)21.6
    Number of Phases1
    Frequency [Hz] 50

    1) up to Panda 15000 / 12-4 cosPhi 0,85 for short take-off power to inductive loads, otherwise cosPhi1
    1) from Panda 18 /17-4 on cosPhi 0,85 optional startup performance with compensation or starting current boost, otherwise cosPhi1

    Three Phase Version (Optional)

    Alternator TypeHP3
    Nominal Voltage in Volt [V]400
    Power rating factor Cos Pi0.85
    Nominal Performance in kW1)20.4
    Nominal Performance in kVA1)24.0
    Continuous Performance in kW1)18.4
    Continuous Performance in kVA1)21.6
    Number of Phases3
    Frequency [Hz]50

    1) up to Panda 15000 / 12-4 cosPhi 0,85 for short take-off power to inductive loads, otherwise cosPhi1
    1) from Panda 18 /17-4 on cosPhi 0,85 optional startup performance with compensation or starting current boost, otherwise cosPhi1

    3 Phase + 1 Phase (230V + 400V) (Optional)

    The Alternator Type "DVS" (Dual Voltage System) comprises of two seperate windings (1-phase and 3-phase) within the stator. The windings are electrically isolated within same stator. This alternator type has a 12% reduction in performance, compared to the HP1 resp. HP3 winding type because the cross-section of the windings are reduced in order to fit both windings within the housing.

     DVS Winding - 1 phaseDVS Winding - 3 phase
    Alternator TypeDVS
    Nominal Voltage in in Volt [V]2303x400+N
    Power rating factor Cos Pi0.850.85
    Number of Phases31
    Nominal Performance (P) in kW1)18.018.0
    Nominal Performance (S) in kVA1)21.221.2
    Continuous Performance in kW1)16.216.2
    Continuous Performance in kVA1)19.119.1
    Rated current each Phase in Ampere [A]45.0 
    Continuous current each Phase in Ampere [A]40.5 
    Frequency [Hz]5050

    1) up to Panda 15000 / 12-4 cosPhi 0,85 for short take-off power to inductive loads, otherwise cosPhi1
    1) from Panda 18 /17-4 on cosPhi 0,85 optional startup performance with compensation or starting current boost, otherwise cosPhi1

    The technical parameters / output performance may vary for different generator types and exhaust emission norms for different countries.

    All performance data applies to generator operation at 100m above sea level at 20°C. Performance reductions can occur when operating at greater heights.

    Engine Data

    Engine ManufacturerKubota (KU)
    Engine TypeV1505
    No. Cylinders4
    Displacement [cm3]1498
    Starter System12V (24V Optional)

    Sound Insulation Cover (Generator Housing / Sound Shield)

     

    VersionMPL 4DS
    Article NumberGVS: 0015348
    CAD REF:0005332
    Drawing Ref.FP1-024298
    Sound Cover TypeMPL (Metal Professional Line)
    Sound Insulation Material4DS
    Dimensions Housing    L x W x H *) *)) Refer to Capsule Drawing of Sound Shield
    Total Weight of Generator with Capsule Refer to Capsule Drawing of Sound Shield
    Sound Cover Upgrade Options (on request)->MPL 6DS

    Disclaimer

    All technical data and specifications including dimensions, performance data, weight and material specifications are only valid when they are explicitly expressed in writing. All data should be considered only for approximation purposes because the data from these sources is gathered from current and previous models. As a result of continual product improvement and modification, the validity of technical data from these sources cannot be guaranteed. 3D-models are only provided on special request. It is the responsibility of the customer to ensure in all cases when ordering that technical data is valid and that the specifications meet his/her requirements.

    *) The dimensions are for the sound insulation housing ONLY and do not include additional parts or fittings such as fasteners, closures or mounting brackets etc.

    Therefore please note: You must consider the additional space will need to be calculated for the installation. This is of importance when planning the installation with respect of cables, hoses and mounting feet.

    **) Generators with DVS windings are slightly longer than those with HP1 or HP3 windings. Specific dimensions are available on request.

    Documentation

    Control - P6+ (p6+)

    Articlenumber :

               
     

    Generator Handbook / Operators Manual

      

    Capsule / Sound shield Drawing : FP1-024298

    Articlenumber:0015348
    High Resolution Image: Panda 24 PVK-UK (p24 n pvk-uk p2.jpg) 
    High Resolution Image: Panda 24 PVK-UK (p24 pvk-uk p1.jpg) 
    High Resolution Image: Panda 24 PVK-UK (p24 pvk-uk p2.JPG) 

    Service- / installation kits and shock mountings