Model.: | Panda 10000i PVK-U |
Generator Type | Panda i-Series (50 Hz)
|
Generator Family | 10000i
|
Generator Version.: | PVK-U
|
Article number.: | 0005536 |
Additional Features |
|
Area of Application.: | Vehicle Generator (V) |
Frequency [Hz] | 50 |
Generator manufacturer | Fischer Panda GmbH |
Isolation class of windings | H |
Nominal Speed [rpm] | 2200-2800 rpm |
Voltage Regulation | iControl |
Voltage Tolerance | ±3% |
Power rating factor Cos Pi | 0.8 |
Engine Speed [rpm] | 2200 - 2800 |
Nominal Voltage in Volt | 230 |
Nominal Performance in kW)1) | 0-8 |
Nominal Performance in kVA1) | 0-10.0 |
Continuous Performance in kW1) | 0-7.2 |
Continuous Performance in kVA1) | 0-9.0 |
Number of Phases | 1 |
Max. Rated Inrush Current in Ampere | |
Frequency [Hz] | 50 |
1) cosPhi 0,8 up to 40°C ambient temperature, otherwise cosPhi 1 up to 50°C
The technical parameters / output performance may vary for different generator types and exhaust emission norms for different countries.
All performance data applies to generator operation at 100m above sea level at 20°C. Performance reductions can occur when operating at greater heights.
Engine Manufacturer | Kubota (KU) |
Engine Type | Z602 |
No. Cylinders | 2 |
Displacement [cm3] | 599 |
Starter System | 12V (24V Optional) |
Version | MPL 4DS |
Article Number | GVS: 0005536 CAD REF:0013502 |
Drawing Ref. | FP1-046227 |
Sound Cover Type | MPL (Metal Professional Line) |
Sound Insulation Material | 4DS |
Dimensions Housing L x W x H *) *)) | Refer to Capsule Drawing of Sound Shield |
Total Weight of Generator with Capsule | Refer to Capsule Drawing of Sound Shield |
Sound Cover Upgrade Options (on request) | ->MPL 6DS |
Disclaimer
All technical data and specifications including dimensions, performance data, weight and material specifications are only valid when they are explicitly expressed in writing. All data should be considered only for approximation purposes because the data from these sources is gathered from current and previous models. As a result of continual product improvement and modification, the validity of technical data from these sources cannot be guaranteed. 3D-models are only provided on special request. It is the responsibility of the customer to ensure in all cases when ordering that technical data is valid and that the specifications meet his/her requirements.
*) The dimensions are for the sound insulation housing ONLY and do not include additional parts or fittings such as fasteners, closures or mounting brackets etc.
Therefore please note: You must consider the additional space will need to be calculated for the installation. This is of importance when planning the installation with respect of cables, hoses and mounting feet.
**) Generators with DVS windings are slightly longer than those with HP1 or HP3 windings. Specific dimensions are available on request.
Control - iControl (icontrol) Articlenumber : ![]() ![]() ![]() ![]() ![]() | ||
Generator Handbook / Operators Manual | ||
Articlenumber:0005536 | ||
High Resolution Image: Panda 10000i PVK-U (10000i pvk-uk p1.jpg) |
Note: Actual Service- / installation kits and shock mountings may differ from those displayed depending on Generator type.
Service kit
0006386
Service Kit "PLus"
21.03.10.061
Shock-mounting, captive
0002753