Panda 60i PVM-NE

General Technical Data

Model.:Panda 60i PVM-NE
Generator TypePanda i-Series (50 Hz)
  • Digital display
  • Environmentally friendly - low fuel consumption
  • Variable speed - load-dependent
  • Easy to install - reduces costs
  • Small size and low weight - compact installation
  • High starting capacity for air conditioners / diving compressors
  • Highly efficient - maximum energy
  • Pure sinus wave is ideal for sensitive electronics
Generator Family60i
    Generator Version.:PVM-NE
    • Suitable for internal installation
    • Requires external radiator
    • No additional silencer is necessary.
    Article number.:0023245
    Additional Features
      Area of Application.:Vehicle Generator (V)
      Frequency [Hz]50
      Generator manufacturerFischer Panda GmbH
      Isolation class of windingsH
      Nominal Speed [rpm]1400-2600 rpm
      Voltage RegulationiControl2
      Power rating factor Cos Pi0.80

      Electrical Alternator

      Performance Data HP3-INV Coil (Three Phase Version with Inverter Technology)

      Alternator Type "HP3-INV"High Performance 3 phase winding. Produces 3-phase current (400 V).
      230 V single phase is included, but must be distributed to 3 phases.
      Engine Speed [rpm]1400 - 2600
      Alternator TypeHP3
      Nominal Voltage in Volt3x400+N
      Nominal Performance in kW1)0-48.00
      Nominal Performance in kVA1)0-60.0
      Continuous Performance in kW1)0-43.2
      Continuous Performance in kVA1)0-54.0
      Number of Phases3
      Frequency in Hertz [Hz]50


      All performance data applies to generator operation at 100m above sea level at 20°C. Performance reductions can occur when operating at greater heights.

      Engine Data

      Engine ManufacturerHatz (HA)
      Engine Type4H50TIC
      No. Cylinders4
      Displacement [cm3]1952
      Starter System12V (24V Optional)

      Sound Insulation Cover (Generator Housing / Sound Shield)

       

      VersionMPL 6DS
      Article Number0023245
      CAD REF:0023246
      Drawing Ref.FP1-054662
      Sound Cover TypeMPL (Metal Professional Line)
      Sound Insulation Material6DS
      Dimensions Housing    L x W x H *) *)) Refer to Capsule Drawing of Sound Shield
      Total Weight of Generator with Capsule Refer to Capsule Drawing of Sound Shield
      Sound Cover Upgrade Options (on request)->MPL 6DS

      Disclaimer

      All technical data and specifications including dimensions, performance data, weight and material specifications are only valid when they are explicitly expressed in writing. All data should be considered only for approximation purposes because the data from these sources is gathered from current and previous models. As a result of continual product improvement and modification, the validity of technical data from these sources cannot be guaranteed. 3D-models are only provided on special request. It is the responsibility of the customer to ensure in all cases when ordering that technical data is valid and that the specifications meet his/her requirements.

      *) The dimensions are for the sound insulation housing ONLY and do not include additional parts or fittings such as fasteners, closures or mounting brackets etc.

      Therefore please note: You must consider the additional space will need to be calculated for the installation. This is of importance when planning the installation with respect of cables, hoses and mounting feet.

      **) Generators with DVS windings are slightly longer than those with HP1 or HP3 windings. Specific dimensions are available on request.

      Cooling: radiator / fans for vehicle generators

      Documentation

      Service- / installation kits and shock mountings

      Note: Actual Service- / installation kits and shock mountings may differ from those displayed depending on Generator type.